Free US Shipping over $500*

Radwag MA 110.5Y.IC.NS ELLIPSIS 5Y SERIES Moisture Analyzer, ø90, h= 8mm, 110 g x 1 mg/ 0.001%

Radwag  |  SKU: MA 110.5Y.IC.NS
$4,610.40 USD $5,424.00
Shipping calculated at checkout.

Delivery and Shipping

We offer Free US Standart Shipping over $500** - for items below 100lbs (actual and dimensional weight).

  • Our standard shipping method is UPS Ground or FedEx Ground.
  • For items over 100lbs we offer UPS rates.
  • International sales are shipped via USPS, UPS, or DHL, where available.

Returns and Refunds

We have a 30-day return policy, which means you have 30 days after receiving your item to request a return.
You can always contact us for any return question at onlinesales@discountscales.com.

Shipping and handling are non-refundable.

Customer is responsible for shipping item/s for return or exchange.

To accept the return, Item has to be in brand new condition with ALL the parts and accessories that came with the box including the original packaging materials.

25% re-stocking fee or more may be applied depending on a condition of the returned item.

The MA 5Y.IC.NS Moisture Analyzer offers you four drying profiles: standard, mild, fast and step.
The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content.
The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather.
You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent.
The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally.
The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally.
The maximum drying temperature on the MA 5Y.IC.NS Moisture Analyzer is 160°C.
The MA 5Y.IC.NS Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined.
Automatic mode - You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end.
Manual mode - You terminate the measurement yourself by pressing the STOP button.
Time-defined mode - The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage!
User-defined mode - When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure.

Features:

Heating module metal heater
Moisture content repeatability +/-0.05% (sample ~ 2g), +/-0.01% (sample ~ 10g)
Drying temperature range max 160 °C
Leveling system semi-automatic - LevelSENSING
Display mode %MC, %DC, %ATRO MC, %ATRO DC, g, g/kg MC, g/kg DC, -%MC
External mass standard 50 g, 100 g, 200 g (depending on the type of moisture analyzer)
Three-point adjustment at defined temperatures, programmable values (equipment: GT105k-12/Z Control Thermometer)
4 drying profiles (standard, fast, step, mild)
4 modes (automatic, manual, time-defined, user-defined)

Specifications

capacity-g 110.0
carton-dimensions 476×381×346
communication USB-A ×2, USB-C, HDMI, Ethernet, Wi-Fi®, Hotspot
display 10" Color Touchscreen
list-price 5424.00
manufacturer-part-number WL-304-0050
operating-temperature +10 — +40 °C
pan-dimension ø90, h= 8 mm
power-consumption 6 W
power-supply 100V – 120V AC 50/60Hz or 200V-240V AC 50/60Hz
readability-g 0.001
Spec Sheet Spec-Sheet_MA_110.5Y.IC.NS.pdf

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Meta Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Radwag

Radwag MA 110.5Y.IC.NS ELLIPSIS 5Y SERIES Moisture Analyzer, ø90, h= 8mm, 110 g x 1 mg/ 0.001%

$4,610.40 USD $5,424.00

The MA 5Y.IC.NS Moisture Analyzer offers you four drying profiles: standard, mild, fast and step.
The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content.
The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather.
You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent.
The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally.
The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally.
The maximum drying temperature on the MA 5Y.IC.NS Moisture Analyzer is 160°C.
The MA 5Y.IC.NS Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined.
Automatic mode - You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end.
Manual mode - You terminate the measurement yourself by pressing the STOP button.
Time-defined mode - The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage!
User-defined mode - When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure.

Features:

Heating module metal heater
Moisture content repeatability +/-0.05% (sample ~ 2g), +/-0.01% (sample ~ 10g)
Drying temperature range max 160 °C
Leveling system semi-automatic - LevelSENSING
Display mode %MC, %DC, %ATRO MC, %ATRO DC, g, g/kg MC, g/kg DC, -%MC
External mass standard 50 g, 100 g, 200 g (depending on the type of moisture analyzer)
Three-point adjustment at defined temperatures, programmable values (equipment: GT105k-12/Z Control Thermometer)
4 drying profiles (standard, fast, step, mild)
4 modes (automatic, manual, time-defined, user-defined)