Free US Shipping over $500*

Accuris MR9610 SmartReader UV-Vis Microplate Absorbance Reader, 200-1000 nm, Accepts 96 and 384-Well Plates, 115V

Accuris  |  SKU: MR9610
$13,692.17 USD $15,213.53
Shipping calculated at checkout.

Delivery and Shipping

We offer Free US Standart Shipping over $500** - for items below 100lbs (actual and dimensional weight).

  • Our standard shipping method is UPS Ground or FedEx Ground.
  • For items over 100lbs we offer UPS rates.
  • International sales are shipped via USPS, UPS, or DHL, where available.

Returns and Refunds

We have a 30-day return policy, which means you have 30 days after receiving your item to request a return.
You can always contact us for any return question at onlinesales@discountscales.com.

Shipping and handling are non-refundable.

Customer is responsible for shipping item/s for return or exchange.

To accept the return, Item has to be in brand new condition with ALL the parts and accessories that came with the box including the original packaging materials.

25% re-stocking fee or more may be applied depending on a condition of the returned item.

The Benchmark Scientific MR9610 Accuris Smart Reader UV-Vis Microplate Reader has been designed with ease-of-use and fast results in mind. This instrument brings extensive capabilities to the lab bench and is designed for the busy lab with multiple users. The large touch screen command center is extremely user-friendly and allows for fast set up of new protocols as well as modifying and running existing protocols.
MONOCHROMATOR TECHNOLOGY - NO FILTERS NEEDED
The monochromator-based optical system allows for precise selection of wavelengths from 200nm to 1000nm, with no filters required. This range makes the SmartReader UV-Vis useful not only for typical ELISA, Bradford Lowry, and turbidity assays but also for more advanced applications such as the quantitation of nucleic acids and proteins. The SmartReader UV-Vis can be set for Endpoint, Kinetic and Spectral Scanning assays.
HIGH THROUGHPUT CAPABILITY
The MR9610 is designed for efficient processing of multiple samples and accepts standard 96 well plates as well as 384 well plates for high-density screening. The plate layout interface allows for a quick and intuitive setup of a plate well’s contents. Users can highlight and label multiple wells to save time. The display shows a graphical representation of the plate. Users can label each well as required for “known standard”, “unknown sample”, “blank well”, “QC Control well”, “positive control”, “negative control”, and “empty”.
OPTIMIZED RESULTS WITH PLATE SHAKING AND INCUBATION
Controllable plate shaking and incubation allow for optimization of assay results. The shaking speed can be controlled at different intensities with options for timed and pulsed shaking before a reading, or in between readings when performing a kinetic assay. The linear motion efficiently and uniformly mixes all samples in both 96 and 384 well plates. Temperature can be controlled from ambient +5⁰C up to 45⁰C, allowing for the processing of enzyme kinetics, and bacterial growth assays.

Features:

Designed for Efficient Processing of Multiple Samples and Accepts Standard 96 Well Plates as well as 384 Well Plates for High Density Screening
Monochromator-based Optical System Allows for Precise Selection of Wavelengths from 200nm to 1000nm
Controllable Plate Shaking and Incubation Allow for Optimization of Assay Results - 3 Options
Temperature can be controlled from ambient +5°C up to 45°C
Wavelength range: 200 - 1000 nm with 1 nm Steps
Wavelength Precision: ±0.2 nm
Read-out range: 0 - 4.0 OD
Bandwidth: < 2.5nm
Detector: Dual Silicon Photoelectric Detectors for Measurement and Reference
Linearity @450nm: R² > 0 .999 (0.0 – 3.0 Abs)
Accuracy @450nm: 1.0% 0.003 Abs (0 - 2.0 Abs) 2.0% (2.0 - 2.5 Abs)
Precision @450nm: CV < 0.5% in Precision Model CV < 1.0% fast mode
Storage: 16GB Memory, more than 10,000 Test Records can be Stored
Ports: 1 Ethernet, 1 B-type USB, 2 A-type USB

Specifications

brand Accuris
list-price 15213.53
Manual Manual_mr9610.pdf
manufacturer-part-number MR9610
Spec Sheet Spec-Sheet_mr9610.pdf

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Accuris

Accuris MR9610 SmartReader UV-Vis Microplate Absorbance Reader, 200-1000 nm, Accepts 96 and 384-Well Plates, 115V

$13,692.17 USD $15,213.53

The Benchmark Scientific MR9610 Accuris Smart Reader UV-Vis Microplate Reader has been designed with ease-of-use and fast results in mind. This instrument brings extensive capabilities to the lab bench and is designed for the busy lab with multiple users. The large touch screen command center is extremely user-friendly and allows for fast set up of new protocols as well as modifying and running existing protocols.
MONOCHROMATOR TECHNOLOGY - NO FILTERS NEEDED
The monochromator-based optical system allows for precise selection of wavelengths from 200nm to 1000nm, with no filters required. This range makes the SmartReader UV-Vis useful not only for typical ELISA, Bradford Lowry, and turbidity assays but also for more advanced applications such as the quantitation of nucleic acids and proteins. The SmartReader UV-Vis can be set for Endpoint, Kinetic and Spectral Scanning assays.
HIGH THROUGHPUT CAPABILITY
The MR9610 is designed for efficient processing of multiple samples and accepts standard 96 well plates as well as 384 well plates for high-density screening. The plate layout interface allows for a quick and intuitive setup of a plate well’s contents. Users can highlight and label multiple wells to save time. The display shows a graphical representation of the plate. Users can label each well as required for “known standard”, “unknown sample”, “blank well”, “QC Control well”, “positive control”, “negative control”, and “empty”.
OPTIMIZED RESULTS WITH PLATE SHAKING AND INCUBATION
Controllable plate shaking and incubation allow for optimization of assay results. The shaking speed can be controlled at different intensities with options for timed and pulsed shaking before a reading, or in between readings when performing a kinetic assay. The linear motion efficiently and uniformly mixes all samples in both 96 and 384 well plates. Temperature can be controlled from ambient +5⁰C up to 45⁰C, allowing for the processing of enzyme kinetics, and bacterial growth assays.

Features:

Designed for Efficient Processing of Multiple Samples and Accepts Standard 96 Well Plates as well as 384 Well Plates for High Density Screening
Monochromator-based Optical System Allows for Precise Selection of Wavelengths from 200nm to 1000nm
Controllable Plate Shaking and Incubation Allow for Optimization of Assay Results - 3 Options
Temperature can be controlled from ambient +5°C up to 45°C
Wavelength range: 200 - 1000 nm with 1 nm Steps
Wavelength Precision: ±0.2 nm
Read-out range: 0 - 4.0 OD
Bandwidth: < 2.5nm
Detector: Dual Silicon Photoelectric Detectors for Measurement and Reference
Linearity @450nm: R² > 0 .999 (0.0 – 3.0 Abs)
Accuracy @450nm: 1.0% 0.003 Abs (0 - 2.0 Abs) 2.0% (2.0 - 2.5 Abs)
Precision @450nm: CV < 0.5% in Precision Model CV < 1.0% fast mode
Storage: 16GB Memory, more than 10,000 Test Records can be Stored
Ports: 1 Ethernet, 1 B-type USB, 2 A-type USB